Skip to main content

Research Repository

Advanced Search

Double skin façade: modelling technique and influence of venetian blinds on the airflow and heat transfer.

Iyi, Draco; Hasan, Reaz; Penlington, Roger; Underwood, Chris

Authors

Draco Iyi

Reaz Hasan

Roger Penlington

Chris Underwood



Abstract

The demand to reduce building cooling load and annual energy consumption can be optimised with the use of Double Skin Facade (DSF). Computational Fluid Dynamics (CFD) methods are frequently used for the analysis of heat transfer through DSF. However, considerable uncertainty exists regarding few key parameters, such as modelling strategies and the solar heat transmitted to the indoor space as a function of the blind tilt angles and positioning within the façade channel. In this paper we have investigated four modelling strategies and the influence of blind tilt angle and their proximity to the façade walls. The DSF system used in this investigation is equipped with venetian blinds and facades that absorb and reflect the incident solar radiation and transfer the direct solar heat gain into the building. A finite volume discretization method with the SIMPLE solution algorithm of the velocity-pressure coupling involving the low-turbulence k-ε model is used. A ray-traced solar model is coupled with long wave radiation model to solve the complete solar and radiation fields along with convection and conduction fields. On the modelling strategies, three dimensional domains were cast over three computational zones; external zone with solar radiation entering the outer skin of glass; buoyancy-driven air cavity zone with convection and transmitted solar radiation; and an internal zone. Also investigated is the thermal behaviour of the DSF due to the blind tilt angles (30°, 45°, 60°, and 75°) and its position from the facade walls (104 mm, 195 mm, 287 mm and 379 mm). Validations of the results are based on experimental data from the literature and the predicted trends compared very well with the experimental measurements. The heat gain due to direct solar radiation and convection through the facades to the internal space are presented. Comparative analysis of the four modelling strategies shows little variation of the results. The implication is a reduction in complexity and cost of modelling, since the additional effort requires in the CFD modelling is not justified by a significant improvement of the results. The variations of the blinds tilt angles as well as its proximity to façade walls significantly influences the convective flow within the façade cavity and the heat gains to the indoor space.

Citation

IYI, D., HASAN, R., PENLINGTON, R. and UNDERWOOD, C. 2014. Double skin façade: modelling technique and influence of venetian blinds on the airflow and heat transfer. Applied thermal engineering [online], 71(1), pages 219-229. Available from: https://doi.org/10.1016/j.applthermaleng.2014.06.024

Journal Article Type Article
Acceptance Date Jun 12, 2014
Online Publication Date Jun 26, 2014
Publication Date Oct 5, 2014
Deposit Date May 15, 2017
Publicly Available Date Mar 28, 2024
Journal Applied thermal engineering
Print ISSN 1359-4311
Electronic ISSN 1873-5606
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 71
Issue 1
Pages 219-229
DOI https://doi.org/10.1016/j.applthermaleng.2014.06.024
Keywords Double skin facade; Thermal performance; CFD; Modelling strategy; Solar radiation; Heat transfer; Natural convection
Public URL http://hdl.handle.net/10059/2308

Files




You might also like



Downloadable Citations