Abstract

In the last four decades, hypertension doubled to 1.13 billion patients. High blood pressure (BP) is the main risk factor for cardiovascular morbidity and mortality. Arterial stiffness (AS) is a key component and poorly understood part of cardiac vital signs. Pressure-volume loop (PU-Loop) has been used to measure local pulse wave velocity (PWV) which is an indicator of AS [1]. We have been able to measure the PU-Loop non-invasively on palmar digital arteries. Pressure and flow waveforms are measured simultaneously at the same location. The dataset has calculated the normalized PWV of 1.48±0.4 from the slope of the line formed between two early systole points of 20-30%. PU-Loop provides an insight into contractility, preload, and hypertension and correcting factor for pulse transit time estimations.

Citation

JANJUA, G.M., FINLAY, D.D., GULDENRING, D., HADIA, R. and MCLAUGHLIN, J. 2017. Novel non-invasive pressure-volume loop measurement for local pulse wave velocity estimation. In Proceedings of 2017 Computing in cardiology, 24-27 September 2017, Rennes, France. Piscataway: IEEE [online], 44, pages 1-4. Available from: https://doi.org/10.22489/CinC.2017.217-385

Conference Name 2017 Computing in cardiology
Conference Location Rennes, France
Start Date Sep 24, 2017
End Date Sep 27, 2017
Acceptance Date Apr 15, 2017
Online Publication Date Sep 14, 2017
Publication Date Dec 31, 2017
Deposit Date Jun 27, 2022
Publicly Available Date Jun 27, 2022
Publisher Institute of Electrical and Electronics Engineers (IEEE)
Volume 44
Pages 1-4
Series Title Computing in cardiology
Series ISSN 2325-8861; 2325-887X
ISBN 9781538666302
DOI https://doi.org/10.22489/CinC.2017.217-385
Keywords Hypertension; High blood pressure; Cardiovascular morbidity; Pressure-volume loop (PU-Loop); Pulse wave velocity (PWV)
Public URL https://rgu-repository.worktribe.com/output/1677529

Files

JANJUA 2017 Novel non-invasive pressure (560 Kb)
PDF

Copyright Statement
© 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or
promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.




Downloadable Citations