Abstract

Heart rate variability analysis (HRVA) gives valuable insight to the cardiovascular system. Electrocardiogram (ECG) based HRVA has been assessment gold standard but eavesdropping of wearable technology requires the comparison of its surrogacy to an accepted standard. In this study, optical and mechanical measures at distal artery waveform are compared to the electrical signal of the heart. The sensor data of the six healthy volunteers are collated and compared at fiducial points in various time, frequency and non-linear domains for HRVA. We have found that during early systole fiducial location on waveforms can be surrogate to ECG standard and mechanical sensor 2nd derivative proved to be the best among them. Also, the comparative technology shows enormous potential for cardiovascular diagnostic.

Citation

JANJUA, G.M.W., HADIA, R., GULDENRING, D., FINLAY, D.D. and MCLAUGHLIN, J.A.D. 2018. Heartrate variability comparison between electrocardiogram, photoplethysmogram and ballistic pulse waveforms at fiducial points. In Maglaveras, N., Chouvarda, I. and de Carvalho, P. (eds.) Precision medicine powered by pHealth and connected health: proceedings of 3rd International conference on biomedical and health informatics (ICBHI 2017), 18-21 November 2017, Thessaloniki, Greece. IFMBE proceedings, 66. Singapore: Springer [online], pages 171-177. Available from: https://doi.org/10.1007/978-981-10-7419-6_29

Presentation Conference Type Conference Paper (published)
Conference Name 3rd International conference on biomedical and health informatics 2017(ICBHI 2017)
Start Date Nov 18, 2017
End Date Nov 21, 2017
Acceptance Date Sep 1, 2017
Online Publication Date Nov 17, 2017
Publication Date Dec 31, 2018
Deposit Date Jun 27, 2022
Publicly Available Date Jun 27, 2022
Publisher Springer
Peer Reviewed Peer Reviewed
Pages 171-177
Series Title International Federation for Medical and Biological Engineering (IFMBE) proceedings
Series Number 66
Series ISSN 1680-0737
Book Title Precision medicine powered by pHealth and connected health
ISBN 9789811074189
DOI https://doi.org/10.1007/978-981-10-7419-6_29
Keywords Heartrate variability; Electrocardiogram; Photoplethysmogram; Ballistic pulse pressure; Fiducial point
Public URL https://rgu-repository.worktribe.com/output/1677514

Files

JANJUA 2018 Heartrate variability comparison (AAM) (590 Kb)
PDF

Copyright Statement
This version of the contribution has been accepted for publication, after peer review (when applicable) but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1007/978-981-10-7419-6_29]. Use of this Accepted Version is subject to the publisher's Accepted Manuscript terms of use [https://www.springernature.com/gp/open-research/policies/accepted-manuscript-terms] .