Skip to main content

Research Repository

Advanced Search

A low-cost tonometer alternative: a comparison between photoplethysmogram and finger ballistocardiogram and validation against tonometric waveform.

Janjua, Ghalib Muhammad Waqas; Finlay, Dewar; Guldenring, Daniel; Haq, Atta Ul; Mclaughlin, James

Authors

Dewar Finlay

Daniel Guldenring

Atta Ul Haq

James Mclaughlin



Abstract

Hypertension is a silent killer and one-third of its sufferers are unaware of its presence. Tonometric devices, like SphygmoCor, Compilor etc., represent the gold standard in pulse wave velocity (PWV) and augmentation index (AIx) measurements which are limited by their high cost and operational accuracy. Here, we present an alternative technology that is low cost and may be suitable for the 'wearable' setting. We undertook the comparisons of arterial waveforms obtained by photoplethysmogram (PPG) and finger ballistocardiogram (BPP) sensors which were then validated against a SphygmoCor tonometric device. Specifically, the agreement analysis of the augmentation, stiffness, reflection, elasticity, ejection elasticity and dicrotic reflection indexes showed that arterial distension waveform sensing using BPP sensor, has precision and accuracy similar to that of a SphygmoCor tonometric device whilst outperforming the volumetric arterial flow sensing using a PPG sensor, in every index. BPP indexes showed the r 2 fit of up to 0.95 and Spearman's rank correlation up to 0.91 when validated against the SphygmoCor tonometer. The estimated individual transfer functions for the BPP sensor, with reference to SphygmoCor, have accuracies of above 85% and 98% for 2 and 4-element windkessel (WK) models, respectively. The findings reported in this work may also be useful for the development of systems that are beneficial in the early and/or routine detection of hypertension.

Citation

JANJUA, G.M.W., FINLAY, D., GULDENRING, D., HAQ, A.U. and MCLAUGHLIN, J. 2019. A low-cost tonometer alternative: a comparison between photoplethysmogram and finger ballistocardiogram and validation against tonometric waveform. IEEE access [online], 7, pages 142787-142795. Available from: https://doi.org/10.1109/ACCESS.2019.2944212

Journal Article Type Article
Acceptance Date Sep 19, 2019
Online Publication Date Sep 27, 2019
Publication Date Dec 31, 2019
Deposit Date May 3, 2022
Publicly Available Date May 3, 2022
Journal IEEE Access
Electronic ISSN 2169-3536
Publisher Institute of Electrical and Electronics Engineers (IEEE)
Peer Reviewed Peer Reviewed
Volume 7
Pages 142787-142795
DOI https://doi.org/10.1109/ACCESS.2019.2944212
Keywords Augmentation index (AIx); Finger ballistocardiogram (BPP); Cuff-less blood pressure; Electrocardiogram (ECG); Photoplethysmogram (PPG); Pulse wave velocity (PWV); Stiffness index (SI); Reflection index (RI)
Public URL https://rgu-repository.worktribe.com/output/983887

Files




You might also like



Downloadable Citations